Web Analytics Made Easy - StatCounter

Variable Frequency Drive Panel Tenders

Get complete information related to latest Variable Frequency Drive Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Variable Frequency Drive Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Variable Frequency Drive Panel Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :40478840 Due date: 29 May, 202529 May, 2025 52.5 Thousand
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - ship - automatic moisture drainer unit of both hp air compressors (qty - 02) has been found to be malfunctioning resulting in excessive moisture deposition in hp air bottles. following additional defects observed:- (a) demister plates of pressure chamber of drainer unit found deteriorated and drain port chocked due to rust deposition. (b) auto drain solenoid defective. (c) timer control block of auto drain valve defective. (d) wiring circuit not showing continuity. the defects to be rectified and system to be proved for satisfactory operation through competent firm. inway jobs include renewal of defective pressure chamber and defective electronic components.

Central Government And Public Sector

CTN :40477848 Due date: 06 Jun, 202506 Jun, 2025 2.20 Lacs
Tender For supply of ems service te railwaypura - pvdg reneted oump for use , replace 50mm gi b class pipe , sf 3inch half turn valve gi , sf 2inch half turn valve gi , modify 3inch water line by pvdg 3inch flange , modify 3inch water line by pvdg 3inch nipple , modify 3inch water line by pvdg 3 inch tee , modify 3inch water line by pvdg 2.5 inch nipple , modify 3inch water line by pvdg 3 and 2.5 inch socket , modify 3inch water line by pvdg 2.5inch coupler , modify 3inch water line by pvdg 2 inch nipple , modify 3inch water line by pvdg 2 inch tee , sf 50 mm nrv , plumbing work for priming assembly , arrangement of automationof extg water supply by pvdg 5 hp dol starter , arrangement of automationof extg water supply by pvdg 63a 4p changeover mcb , arrangement of automationof extg water supply by pvdg auto timer 24 hrs , arrangement of automationof extg water supply by pvdg wlc , arrangement of automationof extg water supply by pvdg 63a 4p mcb , arrangement of automationof extg water supply by pvdg 3.5c 50 sq mm et , arrangement of automationof extg water supply by pvdg 200 a terminal , sitc 10kvar app capacitor , rewind ex fan ped fan motor upto 200w , rewind ceiling fan motor upto 1400 mm , replace 4 ft 36 w t rod , replace 4 ft 18w led , replace 4 ft 230 v tl starter , replace electronic choke for tl , replace side holder for tl , replace 5 amp piano switch , sdrg 1no 1.5 sq.mm frls cu wire , s drg 2no 1.5 sq.mm frls cu wire , replace 2 module electronic regulator , refill fire extgshr 4.5kgs , pvdg hosepipe for fire extgshr 4.5kgs , sf 12v 26ah battery fda system , conduct fire drill for bldg g plus 3 flr , service 11kv substation with ht panels , repair of substation panel by repacing led ind lamps 220v , repair of substation panel by repacing 2 to 4 a hrc fuse , repair of substation panel by repacing lml1 contactor kit , repair of substation panel by repacing bimettalic ol for blower mn2 , repair of substation panel by repacing spp ol relay mpr1 , repair of substation panel by repacing 8 pin 220v pla relay , repair of substation panel by repacing 0 to 400a ammeter ac , repair of substation panel by repacing 0 to 30 a ammeter ac , repair of substation panel by repacing 0 to 500v voltmeter ac , repair of substation panel by repacing dc ammeter 96mm , repair of substation panel by repacingdc voltmeter 96mm , repair of substation panel by repacing selector switch , b check service of dg set 320 kva , supply smps battery charger 24v 10a , sf 12v 130ah mf battery for ea set , supply brass battery terminals , pvdg led ind lamps 220v ea set , sfixing bradided fuel pipe for ea

CTN :40477505 Due date: 02 Jun, 202502 Jun, 2025 5.37 Lacs
Tender For annual repair and maintenance of to building reading lane president estate new delhi during 2025-27. annual comprehensive maintenance for 10 and 50 lph electronic water purification ewp system cdi based.subwork/packages:annual comprehensive maintenace for 10 and 50 lph electronic water purification ewp system cdi based

CTN :40441716 Due date: 12 Jun, 202512 Jun, 2025 NA
Tender For providing of custom bid for services - repair of 02 in number electronic missile transportation system

CTN :40428054 Due date: 19 Jun, 202519 Jun, 2025 NA
Tender For supply of 200 tr cooling tower with 5.5 kw variable frequency drive panel

Central Government And Public Sector

CTN :40343835 Due date: 26 May, 202526 May, 2025 5.14 Lacs
Tender For supply of call base repair of ems at telephone bhavan - replace 4 ft 36 w t rod , replace 4 ft 18w led , replace 4 ft 230 v tl starter , replace electronic choke for tl , replace side holder for tl , replace 5 amp piano switch , replace 15 amp piano switch , replace 5 amp modular switch , replace 15 amp modular switch , replace 5 amp socket outlet 3pin , replace 15amp socket outlet 3pin , replace 5 amp modular outlet 3pin , replace 15 amp modular outlet , replace 2 module electronic regulator , replace 9w led lamp , rewinding 0.5hp monoblock pump , rewinding 10 hp monoblock pump , pvdg skilled technician , wiringfor l powerwith4sqmm cu , wiring with1.5qmmfrlscuwire , wiringwith4.0sqmmfrlscuwire , sdrg 1no 1.5 sq.mm frls cu wire , s drg 2no 1.5 sq.mm frls cu wire , sdrg 2no 4.0 sq.mm frls cu wire , sf 20mm pvc conduit , sl 2c 6 sq mm xlpe al cable , sl 4c 10 sq mm xlpe al cable , laying cable upto 35sqmm , laying cable 35to95sqmm , laying cable 95sqmm to 185sqmm , endtermi2c6.0sqmm cable , endtermi4c10sqmm cable , endtermi3.5c35sqmm cable , sf 32atpn mcb , sf 40atpn mcb , sf 63atpn mcb , sf 5 to 32a sp mcb , sf 5 to 32a spn mcb , sf 40a dp rccb spn , sf 40a 4p rccb tpn , sf 63a 4p rccb tpn , repalce sreet light with 25 w led in holder , repalce sreet light 25 w led on pole , repalce pvc box , replace heat detector fda system , replace smoke detector fda system , replace mcp fda system , replace ri fda system , replace ri of sounder fda system , refill fire extgshr 4.5kgs , pvdg hosepipe for fire extgshr 4.5kgs , sf 12v 26ah battery fda system , rpair card of fda panel , repair hooter of fda system , repair mcp of fda system , repair ri of fda system , repair pa amplifier of fda system , repair mike of pa fda system , conduct fire drill for bldg , serice 11kv 400a id substation , filteration mineral oil , servicing mv and lt panels incl all , calibartion relays by inj method , replacement 2a hrc fuselink , replacement 63a hrc fuselink , replacement 125a hrc fuselink , replacement 200a hrc fuselink , service of dg set 250 kva , service radiator for ea set 250 kva , supply smps battery charger 10a , sf 12v 130ah battery for ea set , supply brass battery terminals , sf led indi lamps 220 v ac , sfixing bradided fuel pipe for ea , replace blower motor for sac unit , replace blower drum for sac unit , replace condenser motor for sac unit , replace condenser blade for sac unit , replace pcb for ac indoor unit , replace pcb for ac outdoor unit , replace rotary compressor for sac unit , replace 25to35 5 mdf capacitor for ac , replace 25a 2p contactor for ac , replace term box for ac , water service for ac unit , blower service for ac unit , leak test and r22 r 410 gas charge for ac unit , replace 50mm thick filter , sf micro controller for ac unit , replace 25a spn mcb , site visit for ac repair

CTN :40316492 Due date: 02 Jun, 202502 Jun, 2025 4.60 Lacs
Tender For providing of customized amc/cmc for pre-owned products - comprehensive annual maintenance (camc) followed by repair and calibration/stamping of electronic road weigh bridge capacity 50 mt; satyam weighing system; comprehensive maintenance contract (cmc); quarterl..

CTN :40329853 Due date: 19 May, 202519 May, 2025 NA
Tender For supply, erection, installation, commissioning and testing of 132kw vfd (variable frequency drive) panel with 132 kw hd vfd as per details technical specifications and features attached in annexure -a. [ warranty period: 30 months after the date of delivery ]
 Loading, Please wait...

Connect us via What's Up